Compact and Affordable Automated Remote Management

Uplogix Automated Remote Management solutions can automate a majority of the routine maintenance and recovery tasks of an IT admin, but faster, error-free and at a fraction of the cost. Uplogix reduces management complexity by delivering integrated, remote management solutions to provide secure remote access and local, in-depth monitoring, as well as configuration, fault and service level management.

Uplogix 430 Connectivity

ports on the Uplogix 430

The Uplogix 430 provides persistent connectivity to managed devices through both in-band and out-of-band channels—monitoring devices locally, performing maintenance or recovery tasks as needed, and constantly enforcing security policies regardless of the state of the network.

Unparalleled management control is possible by interfacing directly through the console port of the devices it manages. This connection enables always-on, localized, round-the-clock management for your IT infrastructure. With integrated functionality for access, control and enforcement, the Uplogix 430 can automate as much as 70% of routine network maintenance functions and autonomously address the majority of issues that cause network-related outages. Problems that today might require IT staff on-site physically to resolve are detected by the Uplogix 430 in seconds, and fixed in minutes.

The intelligence powering the Uplogix 430 is the Remote Management Operating System (RMOS), which is available in both Advanced and Standard versions. With Advanced RMOS, the Uplogix 430 adds the ability to perform service level verification (SLV). SLV uses synthetic transactions to locally monitor, measure and manage the performance of critical network services and applications from the end-user’s perspective including TCP/IP communications, web-based transactions and voice over IP telephony.

Technical Specifications

Dimensions and Weight

  • Width x Height x Depth: 19.7 cm (7.75 in.) x 4.9 cm (1.94 in.) x 18.1 cm (7.125 in.)
  • Weight: 1.2 kg (2.6 lbs.)

Power Supply

  • External universal power adapter (90-240 VAC, 50/60 Hz), included

Temperature

  • Operating: 0° C to 40° C (32° F to 104° F) at mean sea level
  • Non-operating: -10° C to 60° C (14° F to 140° F) at mean sea level

Humidity

  • Operating: 5% to 95% non-condensing
  • Non-operating: 5% to 95% non-condensing

Altitude

  • Operating: sea level to 10,000 ft.
  • Non-operating: sea level to 30,000 ft.

Regulation

  • FCC Class A, CE, TUV
  • RoHS Compliant
Uplogix' virtual administration solution provides us with an on-site management appliance in locations that are challenging to staff, therefore enabling us to expand service to our customers.”

— Lars Eliassen,
Vice President of Global Operations, RigNet